Respiration Monitoring System of Lung Phantom Using Magnetic Sensor

Imamul Muttakin, David Abraham, Rocky Alfanz, Rohmadi Rohmadi

Abstract


Monitoring vital signs is substantial in healthcare to assist both diagnosis and treatment. This work proposes a means of telemonitoring system at initial stage to observe respiratory pattern on lung phantom. Magnetic sensor module LDC1000 is used to read inductance value of conductive material in relation to distance variation. Therefore, respiration pattern can be observed. In continuous mode, the inspiration inductance value is 8 uH, while expiration is 17 uH, with stoppage is 17 uH. For static measurement, the inspiration inductance value is 7.80 uH, while expiration is 16.46 uH and stoppage is 16.46 uH. Those values could be further referred for vital signs telemonitoring system design based on contactless and portable devices.


Keywords


LDC1000; Lung phantom; Magnetic sensor; Respiration monitoring; Telemonitoring

Full Text:

PDF

References


Sulaiman NH, Samsuri NA, Rahim MKA, Seman FC, Inam M. Design and Analysis of Optimum Performance Pacemaker Telemetry Antenna. Telkomnika (Telecommunication Computing Electronics and Control). 2017; 15(2): 877-882.

Jeong JW, Jang YW, Lee I, Shin S, Kim S. Wearable respiratory rate monitoring using piezo-resistive fabric sensor. World congress on medical physics and biomedical engineering. Berlin. 2009: 282-284.

Padasdao B, Boric-Lubecke O. Respiratory rate detection using a wearable electromagnetic generator. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2011: 3217-3220.

Bagchi S, Chattopadhyay M. Real-time monitoring of respiratory diseases of distantly located elderly impaired patients. Sensing Technology: Current Status and Future Trends I. 2014: 25-40.

Liu JJ, Huang MC, Xu W, Zhang X, Stevens L, Alshurafa N, Sarrafzadeh M. Breathsens: A continuous on-bed respiratory monitoring system with torso localization using an unobtrusive pressure sensing array. IEEE journal of biomedical and health informatics. 2015; 19(5): 1682-1688.

Ojarand J, Pille S, Min M, Land R, Oleitšuk J. Magnetic induction sensor for the respiration monitoring. In Proc. of 10th Int. Conf. on Bioelectromagnetism (icBEM). Tallinn. 2015: 1-4.

Muttakin I, Yeap SY, Mansor MM, Fathil MH, Ibrahim I, Ariffin I, Supriyanto E. Low cost design of precision medical ultrasound power measurement system. International Journal of Circuits, Systems and Signal Processing. 2011; 5(6): 672-682.

LDC1000 Inductance to Digital Converter. Texas Instrument. Datasheet SNOSCX2A. 2013.

Oberhauser C. LDC Target Design. Texas Instrument. Application note SNOA957A. 2016.

Benabdellah A, Abbassi Z, Nakheli A. New Electromagnetic Force-Displacement Sensor. Bulletin of Electrical Engineering and Informatics. 2016; 5(3): 334-339.

Kramer GH, Capello K, Bearrs B, Lauzon A, Normandeau L. Linear dimensions and volumes of human lungs obtained from ct images. Health physics. 2012; 102(4): 378-383.




DOI: https://doi.org/10.11591/eei.v7i1.711

Refbacks

  • There are currently no refbacks.




Bulletin of EEI Stats